This site requires JavaScript to function properly.Please enable JavaScript in your web browser.
Please enter the dimensions (mm) in the horizontal and vertical input fields below...
Please enter the dimensions (mm) in the one of the vertical input fields below...
MINIMUM CLEARANCE ABOVE THE REQUIRED FINISHED FLOOR MUST BE AT LEAST 2000mm
For general office use please select the first option (4.8kN/m²)
Light Industrial Storage
Uniformly distributed load of 4.8kN/m²
Use of a 700kg pallet truck.
Point loads from a shelving of 250kg/bay.
Medium Industrial Storage
Uniformly distributed load of 7.2kN/m²
Use of a 1000kg pallet truck.
Point loads from a shelving of 400kg/bay.
Heavy Industrial Storage
Uniformly distributed load of 10kN/m²
Use of a 1500kg pallet truck.
Point loads from a shelving of 500kg/bay.
Means of escape in the event of fire determines the maximum travel distance to a place of safety, as seen in the images below.
The bottom of staircases should be located as near as possible to an exit. Please indicate if you require 1 or 2 staircases accordingly.
Travel distance max 25m to a "storey exit, i.e. to an external pedestrian door, (not a roller shutter door), or to a fire protected route.
If two routes can be provided, and the angle betweek them is greater than 45°, one of the routes must be within 45m travel distance to a "storey exit", i.e. to an external pedestrian door, (not a roller shutter door), or to a fire protected route.
If you are intending to lift pallets up to the mezzanine, you will require an up and over pallet gate, as shown below.
Please tick the boxes that apply.
If you're planning on using shelving above and below the mezzanine, then a two-tier shelving system may prove to be more cost effective.
Please be aware that this is a hand-loaded system only, however should you require to load pallets of goods to the first floor with a fork lift, a small mezzanine platform complete with a pallet gate can be provided.
Should this be of interest to you, please select 'Yes' below and our design team will contact you to discuss your enquiry in more detail.
Your contact details will only be used for the purpose of providing an estimate and will not be shared with any third party.